Industrial Standard Control, Monitor and Message Store Software

Model: WINCONTROL SERVER

  • Dedicated industrial-quality server computer
  • Runs Service (enhanced) version of AXYS WinControl software
  • Provides control/monitoring of an entire distributed audio system
  • Full fault logging with alerts
  • Incorporates message store for announcements
Compare
Project List
Product Info

WinControl Server is an industrial-standard PC running a proprietary “Service Version” of the WinControl software. This combination allows full control and monitoring of the entire audio system from a central point, plus full control and configuration of the AXYS components. Inclusion of Cerberus units extends the scope of the monitoring to include third- party components. 

All AXYS components are fitted with a bi-directional RS-485 or alternative network interface, allowing the creation of a control network encompassing the entire system.  CobraNet® or DANTE™ enabled devices offer control as well as multichannel digital audio transport over Ethernet. WinControl offers the system supervisor a user-friendly GUI overview of the whole audio system, with rapid access to every parameter of each system component. Faults are reported on-screen and recorded in an event log. Provided that Internet access is available, WinControl can be configured to generate email alerts in response to definable fault conditions. 

The Wave Player plays uncompressed sound files recorded in .wav format at 48 kHz sample rate. The files may be of any duration, and can be set to continuously repeat if desired. An important feature of the Wave player is that a pilot tone may be permanently enabled at the audio outputs. The frequency and level of the tone is adjustable. Other AXYS system components (and some third-party equipment) then monitors the pilot tone to confirm the validity of the audio routing.

Mutli-level password protection is provided as part of WinControl; typically there is a “view only” level, allowing system status to be observed, a “user” level permitting component configuration, etc., and a “service” level which would normally only be available to suitably qualified personnel. 

To remove all possibility of a single point-of-failure, two WinControl Servers may be installed (ideally in different locations), with divergent, redundant interconnection paths (a ring topology is common). Normally, both Servers would interface to the facility’s main SCADA, BMS, or other control and monitoring system. The external system then designates one as a master and the other as slave. Only the master issues control commands, but both Servers perform the monitoring functions and log faults.

  • Dedicated industrial-quality server computer
  • Runs Service (enhanced) version of AXYS WinControl software
  • Provides control/monitoring of an entire distributed audio system
  • Full fault logging with alerts
  • Incorporates message store for announcements
  • Interface with system components via RS-485 or CobraNet® or DANTE™ and external control port
  • Automatic reboot on crash
 